Shafique, Atia and Abbasi, Shahbaz and Ceylan, Ömer and Goeritz, Alexander and Yamamoto, Yuji and Barıştıran Kaynak, Canan and Kaynak, Mehmet and Gürbüz, Yaşar (2018) A behavioral model for high Ge content in Si/Si1-xGex multi-quantum well detector. IEEE Sensors Journal . ISSN 1530-437X (Print) 1558-1748 (Online) Published Online First http://dx.doi.org/10.1109/JSEN.2018.2865033
There is a more recent version of this item available.
PDF
A_Behavioral_Model_for_High_Ge_Content_in_Si-Si1-xGex_Multi-Quantum_Well_Detector.pdf
Restricted to Registered users only
Download (892kB) | Request a copy
A_Behavioral_Model_for_High_Ge_Content_in_Si-Si1-xGex_Multi-Quantum_Well_Detector.pdf
Restricted to Registered users only
Download (892kB) | Request a copy
Official URL: http://dx.doi.org/10.1109/JSEN.2018.2865033
Abstract
This paper presents a behavioral model for a Si/Si1-xGex multi-quantum well (MQW) detector that predicts device characteristics to investigate the effect of increasing Ge content in Si/Si1-xGex MQW. The modeling approach in this work is based on a physical instead of empirical approach which allows to obtain a predictive behavioral analysis of high Ge content with only a few fitting parameters. The model is used to simulate device transfer characteristics with respect to various amounts of Ge content used for Si1-xGex layer in MQW. The simulation results of the proposed model are validated with the experimental data. The simulated and the experimental data are consistent over a wide range of Ge content varied from 30% up to 50%. The primary objective of this work is to optimize Ge content in Si/Si1-xGex MQW detector to achieve desired thermal sensitivity measured in terms of temperature coefficient of resistance (TCR) for a potential microbolometer application. This is the first study in the literature to develop such a highly predictive behavioral model of a Ge-enriched Si/Si1-xGex MQW. The study also presents the effect of including the carbon delta (C-delta) layers at the Si/Si1-xGex heterointerface on the device transfer characteristics. The effect of Ge content on the overall noise is also investigated by the noise characterization of the test devices.
Item Type: | Article |
---|---|
Divisions: | Faculty of Engineering and Natural Sciences > Academic programs > Electronics Faculty of Engineering and Natural Sciences |
Depositing User: | Yaşar Gürbüz |
Date Deposited: | 07 Sep 2018 16:26 |
Last Modified: | 26 Apr 2022 10:00 |
URI: | https://research.sabanciuniv.edu/id/eprint/36418 |
Available Versions of this Item
- A behavioral model for high Ge content in Si/Si1-xGex multi-quantum well detector. (deposited 07 Sep 2018 16:26) [Currently Displayed]