Pehli̇van, Ahmet Selim and Kraljevic, Dario and Triplat, Ivan and Bahçeci, Beste (2022) Critical speed calculation of a refurbishment of 11MW hydro power plant unit. Turkish Journal of Electrical Engineering and Computer Sciences, 30 (3). pp. 644-658. ISSN 1300-0632 (Print) 1303-6203 (Online)
Full text not available from this repository. (Request a copy)
Official URL: https://dx.doi.org/10.55730/1300-0632.3803
Abstract
Hydro generator design is a significant issue in terms of safety, efficiency, and energy production sustainability. One of the most crucial issues about design criteria is to satisfy the needs of the project’s critical speed. In this work, the critical speed calculation of an 11 MW hydro power plant was investigated with several design steps. Numerical solution methodologies were implemented using ARMD™. A generator design was developed, and the implementation of the rotor was carried out in Antalya, Turkey. Vibration and displacements of the hydro generator are adequate. The generator unit is active for 3 years and have never encountered runaway speeds. No critical speed or resonance speed is anticipated for the designed hydro generator unit.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | critical speed; FEM; Hydro unit rotor; resonance; rotor dynamics |
Divisions: | Faculty of Engineering and Natural Sciences > Academic programs > Mechatronics Faculty of Engineering and Natural Sciences |
Depositing User: | Beste Bahçeci |
Date Deposited: | 21 Aug 2022 20:35 |
Last Modified: | 21 Aug 2022 20:35 |