Evaluation of dentin defect formation during retreatment with hand and rotary instruments: a micro-CT study

Yılmaz, Ayça and Helvacıoğlu-Yiğit, Dilek and Gür, Cansu and Ersev, Handan and Kızıltaş, Güllü and Avcu, Egemen and Baydemir, Canan and Abbott, Paul Vincent (2017) Evaluation of dentin defect formation during retreatment with hand and rotary instruments: a micro-CT study. Scanning . ISSN 0161-0457 (Print) 1932-8745 (Online)

[thumbnail of Scanning_2017.pdf] PDF
Scanning_2017.pdf
Restricted to Registered users only

Download (1MB) | Request a copy

Abstract

The purpose of this study was to compare the incidence and longitudinal propagation of dentin defects after gutta-percha removal with hand and rotary instruments using microcomputed tomography. Twenty mandibular incisors were prepared using the balanced-force technique and scanned in a 19.9 mu m resolution. Following filling with the lateral compaction technique, gutta-percha was removed with ProTaper Universal Retreatment (PTUR) or hand instruments. After rescanning, a total of 24,120 cross-sectional images were analyzed. The numbers, types, and longitudinal length changes of defects were recorded. Defects were observed in 36.90% of the cross sections. A total of 73 defects were comprised of 87.67% craze lines, 2.73% partial cracks, and 9.58% fractures. No significant difference in terms of new defect formation was detected between the retreatment groups. The apical and middle portions of the roots had more dentin defects than the coronal portions. Defects in three roots of the PTUR instrument group increased in length. Under the conditions of this in vitro study, gutta-percha removal seemed to not increase the incidence of dentin defect formation, but the longitudinal defect propagation finding suggests possible cumulative dentinal damage due to additional endodontic procedures. Hand and rotary instrumentation techniques caused similar dentin defect formation during root canal retreatment.
Item Type: Article
Subjects: T Technology > TJ Mechanical engineering and machinery
R Medicine > RK Dentistry
T Technology > T Technology (General) > T174.7 Nanotechnology
Divisions: Faculty of Engineering and Natural Sciences > Academic programs > Mechatronics
Sabancı University Nanotechnology Research and Application Center
Faculty of Engineering and Natural Sciences > Academic programs > Electronics
Faculty of Engineering and Natural Sciences
Depositing User: Güllü Kızıltaş
Date Deposited: 09 Sep 2017 15:15
Last Modified: 26 Apr 2022 09:48
URI: https://research.sabanciuniv.edu/id/eprint/33141