Qureshi, Anjum and Gürbüz, Yaşar and Kang, Weng P. and Davidson, Jimmy L. (2009) A novel interdigitated capacitor based biosensor for detection of cardiovascular risk marker. Biosensors and Bioelectronics, 25 (4). pp. 877-882. ISSN 0956-5663
PDF (This is a RoMEO green publisher -- author can archive post-print (ie final draft post-refereeing))
A_novel_interdigitated_capacitor_based_biosensor_for_detection_of_cardiovascular_risk_marker.pdf
Download (1MB)
A_novel_interdigitated_capacitor_based_biosensor_for_detection_of_cardiovascular_risk_marker.pdf
Download (1MB)
Official URL: http://dx.doi.org/10.1016/j.bios.2009.08.043
Abstract
C-reactive protein (CRP) is a potential biomarker whose elevated levels in humans determine cardiovascular disease risk and inflammation. In this study, we have developed a novel capacitive biosensor for detection of CRP-antigen using capacitor with interdigitated gold (GID) electrodes on nanocrystalline diamond (NCD) surface. The NCD surface served as a dielectric layer between the gold electrodes. GID-surface was functionalized by antibodies and the immobilization was confirmed by Fourier transform spectroscopy (FT-IR) and contact angle measurements. The CRP-antigen detection was performed by capacitive/dielectric-constant measurements. The relaxation time and polarizability constants were estimated using Cole-Cole model. Our results showed that the relaxation time constant (tau) of only CRP-antibody was within 10(-16)-10(-13) s, which was increased to 10(-11) s after the incubation with CRP-antigen, suggesting that the CRP-antigen was captured by the antibodies on GID-surface. In addition, polarizability constant(m) of CRP was also increased upon incubation with increasing concentration of CRP-antigen. Our results showed that the response of GID-NCD-based capacitive biosensor for CRP-antigen was dependent on both concentration (25-800 ng/ml) as well as frequency (50-350 MHz). Furthermore, using optimized conditions, the GID-NCD based capacitive biosensor developed in this study can potentially be used for detection of elevated levels of protein risk markers in suspected subjects for early diagnosis of disease.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Nanocrystalline diamond film; Antibody; Capacitive; C-reactive protein; Biosensor |
Divisions: | Faculty of Engineering and Natural Sciences > Academic programs > Electronics Faculty of Engineering and Natural Sciences |
Depositing User: | Yaşar Gürbüz |
Date Deposited: | 30 Dec 2009 17:18 |
Last Modified: | 24 Jul 2019 14:52 |
URI: | https://research.sabanciuniv.edu/id/eprint/13632 |