Design and implementation of capacitive micromachined ultrasonic transducers for high power

Yamaner, Yalçın Feysel and Ölçüm, Selim and Bozkurt, Ayhan and Köymen, Hayrettin and Atalar, Abdullah (2012) Design and implementation of capacitive micromachined ultrasonic transducers for high power. In: 2011 IEEE International Ultrasonics Symposium (IUS), Orlando, FL, USA

This is the latest version of this item.

Full text not available from this repository. (Request a copy)

Abstract

Capacitive micromachined ultrasonic transducers (CMUTs) have a strong potential to compete piezoelectric transducers in high power applications. In a CMUT, obtaining high port pressure competes with high particle velocity: a small gap is required for high electrostatic force while particle displacement is limited by the gap height. On the other hand, it is shown in [1] that CMUT array exhibits radiation impedance maxima over a relatively narrow frequency band. In this paper, we describe a design approach in which CMUT array elements resonate at the frequency of maximum impedance and have gap heights such that the generated electrostatic force in uncollapsed mode, can sustain particle displacement peak amplitude up to the gap height. The CMUT parameters are optimized for around 3 MHz of operation, using both a SPICE model and FEM. The optimized parameters require a thick membrane and low gap heights to get maximum displacement without collapsing membrane during the operation. We used anodic bonding process to fabricate CMUT arrays. A conductive 100 mu m silicon wafer is bonded to a glass wafer. Before the bonding process, the silicon wafer is thermally oxidized to create an insulating layer which prevents break down in the operation. Then, the cavities are formed on the insulating layer by a wet etch. The gap height is set to 100 nm. Meanwhile, the glass wafer is dry etched by 120 nm and the etched area is filled by gold evaporation to create the bottom electrodes. The wafers are dipped into piranha solution and bonding process is done afterwards. The fabricated CMUTs are tested in an oil tank. To eliminate the DC voltage which may cause charging problem in the operation, we tried to drive the CMUT array with large continuous wave signals at half of the operating frequency. We observed 1MPa peak to peak pressure with -23 dB second harmonic at the surface of the array (Fig. 1). The proposed design further extends the operation of CMUTs. Observing low harmonic distortions at high output pressure levels, without any charging problem, make CMUT a big candidate for high power applications.
Item Type: Papers in Conference Proceedings
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Faculty of Engineering and Natural Sciences > Academic programs > Electronics
Faculty of Engineering and Natural Sciences
Depositing User: Ayhan Bozkurt
Date Deposited: 02 Jul 2013 10:52
Last Modified: 26 Apr 2022 09:10
URI: https://research.sabanciuniv.edu/id/eprint/21652

Available Versions of this Item

Actions (login required)

View Item
View Item